TOP BAR

HM series

Compare LEOTEK HM Series pedestrian signal modules with overlapping hand and person indications. Review model specifications, Canadian options and downloads.

Explore related applications: Pedestrian signal applications · All Pedestrian Signal products

Round HM Crosswalk Signal for Canada
Indication:
Hand & Person Overlap
Voltage: 120Vac (80-135Vac)
HM series hand crosswalk signal Module (1)
Indication:
Hand & Person Overlap
Voltage: 120Vac (80-135Vac)
About Us

Why LEOTEK?

Building a Safer, Greener, and Smarter City with AIoT

LEOLab

Lighting & Smart City Solutions

Check our LEOLab pages to find more information.

Contact Us

Need Product Support & Inquiry?

If you need any service, please feel free to contact us!

PROJECT SUPPORT

HM Series FAQs

Answers to common questions about product selection, installation and procurement.

What does the HM overlap module display?

HM presents the Portland Orange hand and Lunar White walking person in an overlapping face, rather than DIL’s side-by-side arrangement. The current square specification identifies TP12H-HM as a 12 × 12-inch full-symbol module. Its table lists 7W for the hand and 7W for the person. Choose it for the approved overlap configuration, with the correct housing and termination.

Specifications & documents
CD-WM-HM-EH-Series 12-inch Pedestrian Signal Module Spec-Sheet

Further reading
16-Inch Pedestrian Signal Modules: Size and Display Guide

Are square U.S. and round Canadian HM versions equivalent?

No. TP12H-HM is the square full-symbol configuration. The Canadian round product identifies TSL-PED-12-HM-CR1, with 6W per hand/person indication. The square sheet also identifies a Canada-only outlined TP12H-HM-C option. Keep format, symbol style, model and approval evidence separate; one 12-inch product’s rating or certification should not be assigned to every HM variant.

Specifications & documents
CD-WM-HM-EH-Series 12-inch Pedestrian Signal Module Spec-Sheet · HM Series 12″ Round Pedestrian Signal Module, Hand & Person Overlap (Canada)

Further reading
Traffic Signal Approval: ITE, ETL and DOT Lists

Can HM directly replace a side-by-side DIL face?

Not on the basis of common symbols alone. HM’s overlapping 12 × 12-inch face differs from the DIL 16 × 18-inch side-by-side assembly. A change needs a housing and approved indication-layout review, including clearance, mounting and termination. If the project is a like-for-like replacement, identify the existing model and face format before selecting the spare.

Specifications & documents
CD-WM-HM-EH-Series 12-inch Pedestrian Signal Module Spec-Sheet · DIL Series 16” x 18” Pedestrian Signal Spec Sheet

Further reading
16-Inch Pedestrian Signal Modules: Size and Display Guide

Does HM include countdown digits?

No. The HM table identifies hand/person overlap only. CD is the separate countdown family; SPC combines hand/person/countdown in one larger face. Select the complete approved arrangement if countdown is needed. Ordering HM alone should not be represented as adding countdown or the other functions of a complete accessible pedestrian crossing.

Specifications & documents
CD-WM-HM-EH-Series 12-inch Pedestrian Signal Module Spec-Sheet · SPC series 16 with18 pedestrian countdown signal module

Further reading
16-Inch Pedestrian Signal Modules: Size and Display Guide

Which electrical characteristics should the cabinet review use?

The current square HM sheet specifies 80–135Vac, power factor above 0.90, THD below 20%, response under 75ms and turn-off voltage above 35Vac. Review the actual model, termination and monitoring behavior with the installed cabinet. The 12Vdc footnote in the combined sheet applies to a separately identified WM walking-person model, not to a generic HM DC option.

Specifications & documents
CD-WM-HM-EH-Series 12-inch Pedestrian Signal Module Spec-Sheet

Further reading
Traffic Signal Approval: ITE, ETL and DOT Lists

What life and warranty claims apply to HM?

The combined square sheet lists a five-year limited warranty and a 70% initial-intensity claim at 100,000 operating hours. A lumen/intensity-maintenance statement does not warrant every module component for 100,000 hours or eliminate cabinet/housing maintenance. Use the applicable written warranty and exact order code for claims, and account separately for field service and replacement work.

Specifications & documents
CD-WM-HM-EH-Series 12-inch Pedestrian Signal Module Spec-Sheet · HM Series 12″ Round Pedestrian Signal Module, Hand & Person Overlap (Canada)

Further reading
Long-Life LED Traffic Signals: Replacement Cost and ROI

What environmental and housing checks remain necessary?

The square sheet lists −40°C to +74°C operation, O-ring sealing and a UV-stabilized polycarbonate lens. Compare its dimension drawing with actual internal clearance and mounting retention, and inspect the signal head and cable entry during retrofit. Module moisture resistance does not compensate for a damaged or incorrectly sealed housing. The round Canadian model requires its own drawing.

Specifications & documents
CD-WM-HM-EH-Series 12-inch Pedestrian Signal Module Spec-Sheet · HM Series 12″ Round Pedestrian Signal Module, Hand & Person Overlap (Canada)

Further reading
16-Inch Pedestrian Signal Modules: Size and Display Guide

How should we maintain an accurate HM spare-parts record?

Record square/round format, full/outlined symbol style, exact model, supply rating, connector and tested cabinet configuration. Identify hand/person power separately and use the actual sequence in an energy estimate. Keeping the Canada-only variants distinct from standard U.S. full-symbol HM prevents an apparently similar overlap face from being ordered with the wrong physical or optical configuration.

Specifications & documents
CD-WM-HM-EH-Series 12-inch Pedestrian Signal Module Spec-Sheet · HM Series 12″ Round Pedestrian Signal Module, Hand & Person Overlap (Canada)

Further reading
Traffic Signal Approval: ITE, ETL and DOT Lists

Selection & project planning

Compare overlapping hand/person modules by physical format, electrical configuration and agency requirements. Confirm installation and operation with the actual signal housing and cabinet.

Select the exact indication and configuration

Compare the cataloged square HM configuration with the round Canadian module. Both use overlapping hand and person indications; confirm the model-specific dimensions, electrical rating and approval documents.

Validate the installation interface

Check housing dimensions, attachment hardware, wiring, clearance and sealing. Review controller and cabinet requirements before selecting the exact replacement configuration.

Define acceptance and commissioning

Verify the required pedestrian sequence under the agency acceptance procedure. Record indication operation and any specified flash, preemption or recovery conditions for the proposed installation.

Document procurement and maintenance

Create a schedule of exact model numbers and required indications, electrical variants, quantities and spare units. Obtain current specifications, installation instructions, applicable approval documentation and written warranty terms. Record the installed configurations so maintenance teams can select the correct replacement.